FET-8920 Flow Meter

零售价

市场价


CIT-8920 Inductive Conductivity /Concentration Transmitter/Controller is a high-precision, cost-effective instrument that integrates conductivity / concentration / TDS / temperature measurement.

It is an electromagnetic induction conductivity sensor that is used to measure the conductivity of conductive ions in strong electrolytes. Or a remote transmitter of percent concentration, suitable for continuous measurement of conductivity or percent concentration in a strong ion concentration environment;

重量

Quantity
-
+

库存

隐藏域元素占位

FET-8920 Flow Meter

CIT-8920 Inductive Conductivity /Concentration Transmitter/Controller is a high-precision, cost-effective instrument that integrates conductivity / concentration / TDS / temperature measurement.

It is an electromagnetic induction conductivity sensor that is used to measure the conductivity of conductive ions in strong electrolytes. Or a remote transmitter of percent concentration, suitable for continuous measurement of conductivity or percent concentration in a strong ion concentration environment;

Category:

Paddle Wheel Inserted Flow Meter

  • Product Description

    ■ Technical performance

    Model

    CIT-8920

    Product

    Inductive Conductivity/Concentration Transfer Controller

    Measurement

    Conductivity

    500μS/cm ~2000mS/cm

    Concentration

    1. NaOH, (0-15) % or (25-50) % ;
    2. HNO₃   (note the Corrosion resistance of the sensor)
    (0-25) % or (36-82) % ;
    3. User-defined concentration curves

    TDS

    250.0ppm~1000ppt

    Temperature

    (0 ~ 120) ℃

    Resolution

    Conductivity

    0.01μS/cm

    Concentration

    0.01%

    TDS

    0.01ppm

    Temperature

    0.1℃

    Accuracy

    Conductivity

    (500~1999) μS/cm, ±1.5% (FS)

    (2~19.9) mS/cm. ±1.0% (FS)

    (20~199) mS/cm,±1.0% (FS)

    (200~2000) mS/cm±1.0% (FS)

    TDS

    1.5 level

    Temperature

    ±0.5℃

    Temperature

    Element

    Pt1000

    Range

    (0~120)℃ linear compensation

    Current output

    Isolated (4~20) mA output, maximum loop resistance 5009
    Accuracy: ±0.1mA

    Control output

    Semiconductor Photoelectric Relay,
    Load Current 50mA(Max), ACDC30V(Max)

    Communication

    RS485, (please check the protocol)

    Power supply

    DC24V±4V

    Max consumption

    ≤2.5W

    Protectionlevel

    IP65

    Working environment

    Temperature: (0~50)℃ Relative Humidity.≤95% RH(non-
    condensing)

    Storage

    Temperature: (-20-60)℃ Relative Humidity≤85%RH(non-
    condensing)

    Installation

    Pipeline mounted/Flow device/Immersion