BSQ-EC3

零售价

市场价


BSQ-EC3 can realize the measurement of 2-way or 3-way conductivity value,EC/ER/PH/ORP series transmitter is mainly used for water quality monitoring sensor signal transmission, through RS485 level to amplify the weak signal output from the sensor for transmission, which can be easily communicated with PLC, configuration software, microcontroller, etc. Communication protocol using standard MODBUS RTU protocol.

重量

Quantity
-
+

库存

隐藏域元素占位

BSQ-EC3

BSQ-EC3 can realize the measurement of 2-way or 3-way conductivity value,EC/ER/PH/ORP series transmitter is mainly used for water quality monitoring sensor signal transmission, through RS485 level to amplify the weak signal output from the sensor for transmission, which can be easily communicated with PLC, configuration software, microcontroller, etc. Communication protocol using standard MODBUS RTU protocol.

Category:

Conductivity Meter

  • Product Description

    ■ Technical performance:

    ● Stability: ±2×10-3FS/24h

    ● Mating electrode: 1.0cm-1 ABS plastic platinum black electrode as standard; other specifications are available.

    ● Electrode thread: 1/2″NPT

    ● Cable length: 5 m standard for plug-in type; 1.5 m standard for quick release type.

    ● Medium temperature: 0~50℃

    ● Electrode withstand pressure: 0.5Mpa

    ● Temperature compensating component: NTC10k

    ● Temperature compensation: 25℃ as the reference, automatic compensation

     

    ■ Resistivity - Technical specifications.

    ● Measurement range: 0 to 18.25MΩ;

    ● Accuracy: 2.0 % (FS)

    ● Stability: ±2×10-3FS/24h

    ● Mating electrodes: standard 0.05cm-1 316L stainless steel electrodes available as plug-in or quick release.

    ● Electrode thread: 1/2″NPT

    ● Cable length: 5 m standard for plug-in type; 1.5 m standard for quick release type.

    ● Medium temperature: 0~50℃

    ● Electrode withstand pressure: 0.5Mpa

    ● Temperature compensating component: NTC10k

    ● Temperature compensation: 25℃ as the reference, automatic compensation

    ● Temperature compensation: 25°C as the base, manual or automatic compensation is optional.

    ● Calibration method: three-point calibration, PH4.00, PH6.86, PH9.18

    ● Power supply: DC12V-28V, 24V machine current <0.1A.

    ● Environmental conditions: (1)Temperature 0~50℃ (2)Humidity≤85%RH

    ● Dimension: 122×72×45mm (L×W×H).

    ● Mounting method: rail mounting.

上一页

下一页

Product Inquiry

If you have any questions or needs, please leave a message or contact us and we will reply you as soon as possible.

Submit