Causes and Solutions for Water Overflow in the FLECKER Control Valve Salt Tank

2025-03-13 16:00

Solution: Adjust and shorten the time setting of the brine draw control valve.

The reasons and solutions for water overflow in the salt tank of FLECKER water softening equipment are as follows:  

 1. Excessive Water Remaining After Brine Draw  

Solution: Adjust and shorten the time setting of the brine draw control valve.  

 2. Blockage of Components Due to Impurities in the Water  

Solution:  

- If the salt valve is clogged, remove the salt valve and clean it.  

- If the injector is clogged, those with some experience in water softening can disassemble and clean it.  

 3. Salt Tank Always Full, Possibly Due to Low Water Level in the Internal Trough  

Solution: Adjust the water level in the trough of the softening equipment.  

The above are the common causes and solutions for water overflow in the salt tank of water softening equipment. In practical use, if your water softening equipment experiences salt tank overflow, you can follow the methods above to troubleshoot and find the corresponding solution!

Contact ChiMay for more information about control valve!